Connection Details Of CardVend Controller Board
All trials of this controller have been conducted with a Asahi Seiko 24 Volt Card Vendor and a Smiley NV2/4 Note Reader (& 12V AstroSys, Parallel, GBA Note Validator). The board will most probably drive other makes and models, but we do not guarantee this. We cannot enter into correspondence about other combinations, sorry. The board incorporates the power supply to drive both units. The input can be 18VAC +/- 10% or 24VDC +/- 10%, the power requirement is 2 Amps. The connections are shown below.
Card Dispenser Plug Type Molex KK 0.1" Pitch
Pin |
Function |
Input/Output |
Active State |
1 |
OV Supply |
Out |
- |
2 |
24V Supply |
Out |
- |
3 |
OV |
Out |
- |
4 |
Payout Card |
Out |
L |
5 |
Card Paid Out OK |
In |
L |
6 |
N/C |
- |
- |
7 |
+5V Via 1K Pull-Up |
Out |
- |
8 |
OV |
Out |
- |
9 |
Card Is Stuck |
In |
L |
10 |
N/C |
- |
- |
11 |
Card Stack Empty |
In |
L |
12 |
N/C |
- |
- |
Note Validator Plug Type Molex KK 0.1" Pitch
Pin |
Function |
Input/Output |
Active State |
1 |
Note 1 Accepted |
In |
L |
2 |
Note 2 Accepted |
In |
L |
3 |
Note 3 Accepted |
In |
L |
4 |
Note 4 Accepted |
In |
L |
5 |
Inhibit Note 1 |
Out |
H |
6 |
Inhibit Note 2 |
Out |
H |
7 |
Inhibit Note 3 |
Out |
H |
8 |
Inhibit Note 4 |
Out |
H |
9 |
N/C |
- |
- |
10 |
Alarm |
In |
L |
11 |
+12 Volt Supply |
Out |
- |
12 |
0 Volt Supply |
Out |
- |
13 |
+V Common |
Out |
- |
14 |
Parallel Select |
Out |
H |
15 |
Chassis Earth (Not 0V) |
Out |
- |
16 |
Meter Drive 0V Switched |
Out |
L |
17 |
Meter Drive Permanent +12V |
Out |
- |
Power Connector Screw Terminals
Pin |
Function |
Input/Output |
Active State |
1 |
18VAC or 24VDC Supply |
In |
- |
2 |
18VAC or 24VDC Supply |
In |
- |
3 |
Door Switch N/O |
In |
- |
4 |
Door Switch Common |
In |
- |
5 |
Meter Drive 0V Switched |
Out |
L |
6 |
Meter Drive Permanent +12V |
Out |
- |
7 |
Chassis Earth (Not 0V) |
- |
- |
8 |
Chassis Earth (Not 0V) |
- |
- |
C:\CardVend\Connect.Doc 20-03-1998